PRODUCT DESCRIPTION:
BASEMENT SEALER CLEAR™ is a clear high-gloss, high-performance commercial grade, concrete & masonry waterproofing coating
for floors and walls and decorative surfaces. Waterproofing resin modified with flexible encapsulated polymers which penetrate into the
masonry for the ultimate in waterproofing protection. This new technology has excellent penetration on porous surfaces and will resist up
to 4 psi of negative or positive hydrostatic pressure, which is the equivalent of an 8.8 foot high wall of water. It will also reduce penetration
by radon gas. BASEMENT SEALER CLEAR™ is formulated with an environmentally friendly biocide to resist mildew growth. Conforms
to ASTM D-7088 Resistance to Hydrostatic Pressure and ASTM D-6904 Resistance to Wind Driven Rain.
1 Gallon
#5865-1
5 Gallon
#5865-5
55 Gallon
#5865-55
Pallet
#5865-36/5
Tote
#5865-250
BASEMENT SEALER CLEAR™ USES:
BASEMENT SEALER CLEAR™ is ideal for interior and exterior use, as well as floors and above grade or below grade masonry walls.
Uses include; floors, basement and masonry walls, poured concrete walls, Split-faced block, concrete and cinder block, stucco, decorative
stone, brick and pre-cast decorative items. Use alone on concrete, or as a vapor barrier under adhesive and flooring. Use a compatible
latex floor coating when subjected to vehicular traffic.
BASEMENT SEALER CLEAR™ can be used on metal, wood, previously painted surfaces and most other surfaces and will only provide
positive waterproofing. Negative hydrostatic pressure resistance can only be achieved on bare uncoated concrete or masonry.
SURFACE PREPARATION:
For proper adhesion and penetration, it is essential that the surface be properly prepared. Surface must be pressure washed with at
least 1500 P.S.I. of pressure using a water and chlorine solution (approximately 1 quart of chlorine to 5 gallons of water). Thoroughly
remove all dirt, oil, grease, residues, mold, mildew, algae and any other surface contaminants. Severe mildew requires a stronger
concentration of chlorine. TSP (Tri-Sodium Phosphate) should be used to clean oil and grease stains. Efflorescence is a white, powdery, crystal-like deposit visible on the masonry. Any EFFLORESCENCE must be removed. Use muriatic
acid to etch and eliminate efflorescence.
MURIATIC ACID CONCRETE ETCHING:
BROOM FINISH: Pressure wash only.
SMOOTH TROWELED CONCRETE SURFACES: (Garage Floors, Interior Warehouse Floors, Etc.)
Smooth surfaces must be acid etched to ensure proper penetration. Use muriatic acid and follow instructions on manufacturers label since concentrations can vary. Visible pores in uncoated concrete must appear before applying the product. Repeat acid etching until visible pores appear in surface. (Surface should feel like 80 grit sandpaper). Rinse the surface well with water and allow it to dry completely for at least 12 hours.
APPLICATION PROCEDURE:
Stir well before and during use. Minimum of two coats required. Do not apply when temperatures are below 50 degrees Fahrenheit
or when humidity is very high. Do not apply when coating will be subjected to rain or heavy dew before it has had enough time to dry
(approx. 3 hours). Do not apply the product to hot surfaces directly in sunlight, this may cause the coating to dry too quickly and
reduce or prevent proper penetration and adhesion. Drying time will vary depending on temperature, humidity and location. Apply
using brush, ¾” roller or spray. If brushed, work BASEMENT SEALER CLEAR™ into the surface, being sure to fill all pores and
pinholes. Apply uniformly and do not leave puddles or build ups. Spread Rate will vary depending on surface. Apply the second coat
after waiting at least 3 hours. Apply a top coat of latex paint after 4 hours. Light foot traffic after 4 hours. Heavy foot traffic after 24
hours. Under floor covering 24 hours. High humidity will increase the cure time.
CLEAN UP: Clean up all spills, tools and overspray immediately while the coating is still wet with warm soapy water.
TROUBLESHOOTING: If leaking persists after coating it indicates that pinholes or pores have not been sealed. Inspect the affected
area closely to locate problem spots and recoat to seal. Then recoat the section again.
Data Sheet - BASEMENT SEALER CLEAR™ Clear Hydrostatic Pressure Resistance Basement Floor Paint Datasheet